35-kV-Öltransformator
20000KVA 35KV
20000KVA 35KV
3150KVA 35KV
| Nennleistung (KVA) | Spannungskombination | Gruppenbezeichnung beitreten | Leerlaufverlust (W) | Lastverlust (W) | Kurzschlussimpedanz (%) | Leerlaufstrom (%) | ||
| Hochspannung (KV) | Tapoff % | Niedriger Druck (KV) | ||||||
| S13-50/35 | 38.5 35 | ±5 ±2x2,5 | 0.4 | Dyn11 Yyn0 | 128 | 1200/1140 | 6.5 | 1.30 |
| S13-100/35 | 184 | 2010/1910 | 1.10 | |||||
| S13-125/35 | 216 | 2370/2260 | 1.10 | |||||
| S13-160/35 | 224 | 2820/2680 | 1.00 | |||||
| S13-200/35 | 272 | 3320/3160 | 1.00 | |||||
| S13-250/35 | 320 | 3950/3760 | 0.95 | |||||
| S13-315/35 | 384 | 4750/4530 | 0.95 | |||||
| S13-400/35 | 464 | 5740/5470 | 0.85 | |||||
| S13-500/35 | 544 | 6910/6580 | 0.85 | |||||
| S13-630/35 | 664 | 7860 | 0.65 | |||||
| S13-800/35 | 784 | 9400 | 0.65 | |||||
| S13-1000/35 | 920 | 11500 | 0.65 | |||||
| S13-1250/35 | 1120 | 13900 | 0.60 | |||||
| S13-1600/35 | 1350 | 16600 | 0.60 | |||||
| S13-2000/35 | 1590 | 19700 | 0.55 | |||||
| S13-2500/35 | 1890 | 23200 | 0.55 | |||||
| Nennleistung (KVA) | Gruppenbezeichnung beitreten | Spannungskombination | Leerlaufstrom % | Leerlaufverlust W | Lastverlust (120℃)W | Impedanzspannung % | ||
| Hochspannung (KV) | Hochdruck-Armaturensortiment % | Niedriger Druck (KV) | ||||||
| SCB10-315/35 | Yyn0 or Dyn11 | 35 or 38.5 | ±5oder ±2×2,5 | 0.4 3.15 6 6.3 10 10.5 11 | 2 | 1160 | 4170 | 6 7 8 9 |
| SCB10-400/35 | 2 | 1360 | 5360 | |||||
| SCBI10-500/35 | 2 | 1600 | 6590 | |||||
| SCB10-630/35 | 1.8 | 1840 | 7680 | |||||
| SCB10-800/35 | 1.9 | 2220 | 9350 | |||||
| SC810-1000/35 | 1.9 | 2640 | 10880 | |||||
| SCB10-1250/35 | 1.7 | 3090 | 12840 | |||||
| SCB10-1600/35 | 1.7 | 3650 | 15390 | |||||
| SCB10-2000/35 | 1.5 | 4200 | 18110 | |||||
| SCB10-2500/35 | 7.5 | 4800 | 21680 | |||||
| SCB10-3150/35 | 1.3 | 5000 | 24400 | |||||
| SC810-4000/35 | 1.3 | 6950 | 29330 | |||||
| SCB10-5000/35 | 1.1 | 8320 | 34770 | |||||
| SCB10-6300/35 | 1.1 | 9840 | 40630 | |||||
| SCB10-8000/35 | Yd11 or Ynd11 | 1 | 11200 | 45050 | ||||
| SCB10-10000/35 | 1 | 12800 | 51200 | 7 | ||||
| SC810-12500/35 | 0.9 | 16150 | 55300 | |||||
| SCB10-16000/35 | 0.8 | 19560 | 59800 | |||||
Einführung in die mehrphasige gleichgerichtete Leistung in Wechselrichtern Mehrphasige Gleichrichtung spielt eine ...
MEHR LESENEinführung Mit dem raschen Wachstum der Urbanisierung, der industriellen Expansion und der In...
MEHR LESENEinführung Transformatoren sind wesentliche Komponenten in elektrischen Stromversorgungssystemen, die ...
MEHR LESENTransformatoren sind wesentliche Komponenten im elektrischen Stromversorgungssystem und dienen dazu, die Spannung...
MEHR LESEN