35-kV-Öltransformator
20000KVA 35KV
20000KVA 35KV
3150KVA 35KV
| Nennleistung (KVA) | Spannungskombination | Gruppenbezeichnung beitreten | Leerlaufverlust (W) | Lastverlust (W) | Kurzschlussimpedanz (%) | Leerlaufstrom (%) | ||
| Hochspannung (KV) | Tapoff % | Niedriger Druck (KV) | ||||||
| S13-50/35 | 38.5 35 | ±5 ±2x2,5 | 0.4 | Dyn11 Yyn0 | 128 | 1200/1140 | 6.5 | 1.30 |
| S13-100/35 | 184 | 2010/1910 | 1.10 | |||||
| S13-125/35 | 216 | 2370/2260 | 1.10 | |||||
| S13-160/35 | 224 | 2820/2680 | 1.00 | |||||
| S13-200/35 | 272 | 3320/3160 | 1.00 | |||||
| S13-250/35 | 320 | 3950/3760 | 0.95 | |||||
| S13-315/35 | 384 | 4750/4530 | 0.95 | |||||
| S13-400/35 | 464 | 5740/5470 | 0.85 | |||||
| S13-500/35 | 544 | 6910/6580 | 0.85 | |||||
| S13-630/35 | 664 | 7860 | 0.65 | |||||
| S13-800/35 | 784 | 9400 | 0.65 | |||||
| S13-1000/35 | 920 | 11500 | 0.65 | |||||
| S13-1250/35 | 1120 | 13900 | 0.60 | |||||
| S13-1600/35 | 1350 | 16600 | 0.60 | |||||
| S13-2000/35 | 1590 | 19700 | 0.55 | |||||
| S13-2500/35 | 1890 | 23200 | 0.55 | |||||
| Nennleistung (KVA) | Gruppenbezeichnung beitreten | Spannungskombination | Leerlaufstrom % | Leerlaufverlust W | Lastverlust (120℃)W | Impedanzspannung % | ||
| Hochspannung (KV) | Hochdruck-Armaturensortiment % | Niedriger Druck (KV) | ||||||
| SCB10-315/35 | Yyn0 or Dyn11 | 35 or 38.5 | ±5oder ±2×2,5 | 0.4 3.15 6 6.3 10 10.5 11 | 2 | 1160 | 4170 | 6 7 8 9 |
| SCB10-400/35 | 2 | 1360 | 5360 | |||||
| SCBI10-500/35 | 2 | 1600 | 6590 | |||||
| SCB10-630/35 | 1.8 | 1840 | 7680 | |||||
| SCB10-800/35 | 1.9 | 2220 | 9350 | |||||
| SC810-1000/35 | 1.9 | 2640 | 10880 | |||||
| SCB10-1250/35 | 1.7 | 3090 | 12840 | |||||
| SCB10-1600/35 | 1.7 | 3650 | 15390 | |||||
| SCB10-2000/35 | 1.5 | 4200 | 18110 | |||||
| SCB10-2500/35 | 7.5 | 4800 | 21680 | |||||
| SCB10-3150/35 | 1.3 | 5000 | 24400 | |||||
| SC810-4000/35 | 1.3 | 6950 | 29330 | |||||
| SCB10-5000/35 | 1.1 | 8320 | 34770 | |||||
| SCB10-6300/35 | 1.1 | 9840 | 40630 | |||||
| SCB10-8000/35 | Yd11 or Ynd11 | 1 | 11200 | 45050 | ||||
| SCB10-10000/35 | 1 | 12800 | 51200 | 7 | ||||
| SC810-12500/35 | 0.9 | 16150 | 55300 | |||||
| SCB10-16000/35 | 0.8 | 19560 | 59800 | |||||
Warum die Wartung von Trockentransformatoren nicht vernachlässigt werden darf A Trockentransformator ...
MEHR LESENA Verteilungstransformator sitzt auf der letzten Stufe des Netzes und wandelt Mittelspannung in Nutzspannung f...
MEHR LESENWas ist ein flüssigkeitsgefüllter Transformator? Ein flüssigkeitsgefüllter Transformator ist ein Leistungstransfor...
MEHR LESENEinführung in die mehrphasige gleichgerichtete Leistung in Wechselrichtern Mehrphasige Gleichrichtung spielt eine ...
MEHR LESEN